Yale SmartHome Alarm series Specifiche Pagina 15

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 14
15
second increments.
•30secondsisthefactorydefault.
Entry Sound
The control unit will beep during the entry delay
period as an entry warning, you can switch the
sound on and off with this setting.
•Entrysoundonisthefactorydefault.
Exit Sound
The control unit will beep during the exit delay period
as an exit warning, you can switch the sound on and
off with this setting.
•Exitsoundonisthefactorydefault.
Door Chime
Any door contact or PIR set to entry will cause
the control unit to chime when activated when the
system is disarmed. This is used to signal when
anyone has entered your premises. You can switch
the sound on and off with this setting.
•Chimeoffisthefactorydefault.
DC Open/Close
If this is turned On, the control panel will sound a
door chime and display a fault message when user
tries to arm the system with Door contact opened.
•DCOpen/CloseOffisthefactorydefault.
LCD Backlight
The control unit display LCD can be turned on
Permanently or set to auto turn off after 30 seconds
of last key pressed.
•Autooffisthefactorydefault.
Key Tone
The control unit can be made to beep when a key is
pressed. Key Tone can be selected to On or Off.
•KeyToneOnisthefactorydefault.
Ring Tone
The control unit can be made to beep when the
phone is ringing, you can switch the sound on and
off with this setting.
•Ringingoffisthefactorydefault.
Alarm Length
The siren (both external and built-in) will sound when
an alarm is activated. The length of the alarm can be
set from 1 to 10 minutes in 1 minute increments with
this setting.
•3minutesisthefactorydefault.
C.U. Siren
You can disable the control unit’s built-in siren with
this setting.
•Sirenonisthefactorydefault.
Jamming Det
Enable or disable Jamming/Interference detection on
the control panel. Confirmed by pressing the 3 key.
Default setting is Disable (recommended).
KF Entry
When selected as Off, user must first trigger an entry
sensor before the keyfob can disable the system.
Please select On if you which to disarm the system
without first triggering an entry sensor.
•KFEntryOffisthefactorydefault.
•IftheKeyfob’sPanicbuttonistriggered,the
same keyfob cannot be use for disarming the siren.
Tamper Alarm
If set to Away Arm only, it will trigger the alarm when
tamper is active under away arm mode (also known
as full arm). It will only give a fault LED indication in
all other mode. If set to Normal, a tamper condition
will always triggers a burglar alarm under disarm,
home arm and away arm mode.
•AwayArmOnlyisthefactorydefault.
Mobility CHK (for elderly or infirm)
If there is no movement around the house for a
preset period of time (from home omit sensors under
part arm and all sensors under disarm mode), an
emergency alarm will be activated and reported over
the telephone line. Any key presses on the panel
and entry sensor triggering will reset the countdown
timer. The monitoring can be disabled or set at 4, 8
and 12 hour.
•Disableisthefactorydefault.
Siren Delay
This setting allows a delay before the control unit
and external sirens are activated. You might want to
use this if you do not want the control unit to draw
attention to itself during an alarm, to give it time to
dial out on the telephone line. The delay can be set
from Disable (no delay) to 10 minutes in increments
of 1 minute.
•Disableisthefactorydefault.
Warning Beep
The control unit will give a reminder beep every 30
seconds in the event of a system fault, such as
tamper or a low battery etc. This setting allows this
feature to be switched on and off.